Monday to Friday - 7:30am to 4:30pm
Categories

Categories

Information

TIMEGUARD RCD05WAVN RCD 2-GANG WHITE SOCKET

The Timeguard RCD05WAVN is a double-gang active / non-latching RCD protected switched socket in white, with a mechanical safety flag system.

Timeguard's dual flag RCD technology is a safety feature that provides additional safety to both the installer and end user by showing clear visual indication as to the status of the RCD. A red flag shows the device is on with a live supply to the appliance, while a green flag shows the device is safe with the supply to the appliance switched off.

Timeguard's new range of Valiance Plus RCDs are fully approved and certified to the new BS7288:2016 standard which now demands a higher resilience to RF devices (e.g. mobile phones, walkie-talkies, electronic equipment, etc.), resulting in lower nuisance tripping compared to RCDs built to the old BS standard.

Features:

  • Dual flag technology provides added protection against the risks of electrocution
  • High EMC immunity dramatically reduces nuisance tripping
  • Continues to protect with lost neutral / pulsating DC earth fault
  • 3-year guarantee

Specifications:

  • Operating voltage: 230V AC 50Hz
  • Max current: 13A
  • Rated trip current: 30 mA
  • Trip speed: Less than 40 ms at 150 mA residual current
  • RCD type: Double-pole, active (non-latching)
  • Breaking capacity: 250A (earth leakage)
  • Operating temperature: -5 °C to 40 °C
  • Size: 85 mm x 145 mm x 43 mm
  • Fixed cable capacity: 1 x 8 mm² or 2 x 4 mm² or 3 x 2.5 mm²
  • CE compliant: Yes
  • Standards: BS7288:2016, BS1363-2, latest IET Wiring Regulations

Stock Code: SMIRCD05W